
1
SPM412e Controller Instructions
Controller
(Biamp #909-0128-00): The Controller is a ‘hard-wired’ control, which is
powered by the SPM412e. There are no batteries to wear out, and it is not easily lost or
stolen. The Controller may be wired up to 2000 feet from the SPM412e, using 2-
conductor shielded cable (not included). The Controller overrides all similar commands
which might be initiated from the front panel of the SPM412e (see NOTE below). To
install Controller, first remove mounting box from circuit board & front panel. Route
cable through ‘knock-out’ hole on rear of mounting box. Install mounting box in wall or
panel. Three screw terminals on circuit board (‘GND’, ‘IR2’, & ‘IR3’) correspond to
‘Remote’ terminals on rear panel of SPM412e. Connect cable shield to ‘GND’ terminals
at each end. Use conductors to connect ‘IR2’ to ‘IR2’ & ‘IR3’ to ‘IR3’. Install circuit
board & front panel on mounting box. The Controller has seven buttons which control
functions on the SPM412e. The Channel Select buttons & indicators provide the same
functions as Channel Select on the SPM412e front panel (including the ability to select
more than one stereo line input at a time). The Main Level buttons & display provide the
same functions as Main Level on the SPM412e front panel (except that only a single
indicator will light to display the level setting, and it will dim when the output is muted).
The Controller also includes an infrared detector, which allows it to operate as an
Infrared Receiver. (The Controller responds only to SPM412e & VSX41 infrared
commands. Infrared commands intended for other BIAMP products will not be sent
through to the VSX41 Remote Output.) NOTE: Two additional screw terminals (‘GND’
& ‘KEY SWI’) allow an external key-switch (or contact-closure) to ‘lock-out’ control of
Channel Select and/or Main Level functions. These functions will then be temporarily
available from the SPM412e front panel, as long as the ‘lock-out’ is maintained. When
‘lock-out’ is released, the Controller memory will then reassert its previous settings on
the SPM412e. A 4-gang DIP switch on the Controller circuit board allows custom
functions to be assigned, such as Channel Select ‘lock-out’, Main Level ‘lock-out’, key-
lock normally-open/closed, and infrared detector defeat (see Installation on page 3).
MAIN LEVEL
SPM412e Controller
CHANNEL SELECT
1
2
3
4
max
min
MUTE
NOTE: An SPM412e may be used in conjunction with a VSX41, to provide simultaneous switching of both audio & video sources. When
this is done, the desired remote control is wired to the VSX41. Then the ‘Remote Output’ of the VSX41 is wired to the SPM412e.
Comentarios a estos manuales